This article applies to FIMSync (update 2), which will be further referenced as "sync engine".
You can get the following message when the connector can not connect to Lotus Notes: < error>The management agent run could not start as there where connection errors.</error> If the event viewer shows:
"Microsoft.MetadirectoryServices.FailedConnectionException ---> System.Runtime.InteropServices.COMException: Retrieving the COM class factory for component with CLSID {29131539-2EED-1069-BF5D-00DD011186B7} failed due to the following error: 80040154 Class not registered (Exception from HRESULT: 0x80040154 This is probably because you have not selected 'X86' as the architecture in the management agent. You should do this because this is the only mode that the connector supports.
If you keep getting this message, restart the create management agent wizard.
Richard Mueller edited Revision 6. Comment: Removed (en-US) from title, modified title casing, added tag
Peter Geelen edited Revision 2. Comment: consolidated layout