  • Wiki Page: Forefront UAG Troubleshooting: Event ID 167: The KCD Shadow User Name Claim Cannot Be Retrieved

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " You are not authorized to access this application. " There may also be an event 167 in the event viewer or in the Web Monitor with the description " The KCD shadow user name...
  • Wiki Page: How to Attach a Custom Task to an Event on Windows Server 2008

    In an earlier post I talked about how to forward events from one machine to another. That works out quite well, but unless you’re sitting at the log and watching the events go by, you might miss something. You might agree that there are some events that you are more interested in than others. For example...
  • Wiki Page: Forwarding Events from Windows Server 2008 Server Core DC

    There were some changes between Windows Server 2008 and Windows Server 2008 R2, the one I am interested in is WinRM. The default HTTP port on Windows Server 2008 is TCP 80, but on Windows Server 2008 R2 the default HTTP port is TCP 5985. There are a couple of ways to get around this: either change...
  • Wiki Page: Forefront UAG: Troubleshooting Forefront UAG with AD FS 2.0 Event Viewer Messages

    This topic lists the messages that you may encounter on Forefront Unified Access Gateway (UAG) in the event viewer or in the Forefront UAG Web Monitor when end users attempt to access your published site using Active Directory Federation Services (AD FS) 2.0 authentication. Event ID/Web...
  • Wiki Page: Getting Event Log Contents by Email on an Event Log Trigger

    I worked on the following PowerShell Script to email event log content (for example, event ID 4720 that shows the user creation on DCs) which is already triggered by event viewer with "running program" option (you must run "powershell -filter "<script path>""). Please...
  • Wiki Page: Taking Backup of Event Viewer Once or on a Scheduled Basis

    Why do we need to take the Backup of the Event Viewer: These days as we know a server is hosting huge number of applications and services, the Event Viewer logs can come in handy if we want to troubleshoot any performance issues. So for doing that we need to take the backup of the Application and...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 158: The Application Settings Could Not Be Read

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " An unexpected error occurred when starting the application. " There may also be an event 158 in the event viewer or in the Web Monitor with the description " ADFSv2Site: The...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 165: The Single Sign-Out for a User Was Not Complete

    Symptoms — End users click the Log Off button in the Forefront UAG portal and are logged out of the portal, but an event 165 appears in the event viewer or in the Web Monitor with the description " ADFSv2Site: Single sign out process for user with lead user claim value [user_name] was not complete...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 159: The Trunk Received a Request with More than One Identity

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " A request was received with an incorrect number of identities. Only single identity requests are supported. " There may also be an event 159 in the event viewer or the Web Monitor...
  • Wiki Page: SharePoint 2010: Event Logs in Incorrect Language

    This issue does not occur frequently. It occurs randomly and I am not certain of its cause yet. Recently, I slipstreamed the installation of eight Server 2010 Language Packs for SharePoint, Project Server and Office Web Apps (OWA). Also, the SharePoint 2010 Diagnostic and Logging page in Central...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 160: The Authentication Request for the Site Does Not Match the Expected Trunk Name

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " The trunk name in the received request does not match the expected trunk name. " There may also be an event 160 in the event viewer or in the Web Monitor with the description "...
  • Wiki Page: Analysis Services Event ID and Event Descriptions

    These event IDs and event descriptions are for SQL Server Analysis Services (SSAS) , a SQL Server tool. Applies to: SQL Server 2005 (except where noted), SQL Server 2008, SQL Server 2008 R2, SQL Server Code-named“Denali”. For more information about specific event errors, look it up on ...
  • Wiki Page: SharePoint 2010: MsiInstaller Errors (1015)

    When I try to use User Profile Application via Central Administration the following warnings are logged in the Event Viewer: Source : MsiInstaller Event ID : 1004 Level : Warning Keywords : Classic User : NETWORK SERVICE Description : Detection of product '{90140000-104C...
  • Wiki Page: ID de evento do Analysis Services e descrições de eventos (pt-BR)

    Esse artigo foi originalmente escrito em: Analysis Services Event ID and Event Descriptions Essas IDs de evento e descrições de evento são para SQL Server Analysis Services (SSAS) , uma ferramenta do SQL Server . Aplica-se a: SQL Server 2005 (exceto quando indicado), SQL Server 2008, SQL...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 152: User Could Not Be Signed Out

    Symptoms — End users click the Log Off button in the Forefront UAG portal and are logged out of the portal, but an event 152 appears in the event viewer or in the Web Monitor with the description " WS-FAM: User with lead user claim value [user_name] could not be signed out. Session ID [session_ID...
  • Wiki Page: Performance Improvement Checklist for Asp.Net/ MOSS Applications

    Here is the active checklist i have prepared for enchaining web application performance .. 1 e-Commerce web site Turn off Session State, if not required Disable View State of a Page if possible ...
  • Wiki Page: Computer Management

    Table of Contents Introduction Tasks available via Computer Management Options for remote Computer Management Option 1 Option 2 Introduction Microsoft Windows XP and later OSes include the Computer Management tool (Compmgmt.msc) in the Administration Support Tools component. You can use the Computer...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 161: The User Name Claim Type Is Missing from the Security Token

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " The request cannot be completed. User details are missing. Contact the site administrator. " There may also be an event 161 in the event viewer or in the Web Monitor with the description...
  • Wiki Page: Cannot open the Event Viewer in Windows 2008 server

    Operating Systems Windows 2008 server, Windows 7,Windows Vista Problem While opening event viewer showing the error MMC could not create the snap-in. CLSID: FX:{18ea3f92-d6aa-41d9-a205-2023400c8fbb} Solution Boot the system...
  • Wiki Page: Tipos de Logon do Windows (pt-BR)

    Como alguns ja devem saber, o Windows gera eventos de logon, porém, nem sempre o termo “logon” esta relacionado aquele em que o usuário esta de frente para o computador. Abaixo irei descrever brevemente cada tipo de logon: 0 e 1 – System: Usado pela conta System...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 176: Too Many Claims with the Lead User Name Claim Type

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " An authentication error occurred when signing in. " There may also be an event 176 in the event viewer or in the Web Monitor with the description " ADFSv2Site: Found more...
  • Wiki Page: Forefront UAG Troubleshooting: Event ID 151: User Could Not Be Signed In

    Symptoms — When end users attempt to access the Forefront UAG portal, they may receive the following message " An authentication error occurred when signing in. " There may also be an event 151 in the event viewer or in the Web Monitor with the description " WS-FAM: User with lead...
  • Wiki Page: Auditoria de logon no Windows Server 2008 R2 (pt-BR)

    Table of Contents Introdução Habilitando a auditoria de logon em servidores Stand Alone. Habilitando a auditoria de logon em servidores membros de um domínio do Active Directory Consultar Logs de Segurança Código e Descrição de tipos de logon Código...
  • Wiki Page: Remote Troubleshooting Tools

    Program Name Syntax Computer Management compmgmt.msc /computer:<Computername> Local Users and Groups lusrmgr.msc /computer:<Computername> Event Viewer Eventvwr.exe /computer:<Computername> Powershell Powershell...
  • Wiki Page: Atualizando o Domínio para Windows Server 2008 - Examinando Eventos no Event Viewer - Part02 (pt-BR)

    Jordano Mazzoni Twitter: @jordanomazzoni Site: http://jordanomazzoni.com.br Site: http://bit.ly/evkxwu Acompanhe o restante da série no site ou seguindo-me no twitter..!!! Grande abraço Jordano Mazzoni